Cisco Systems N5KC5596TFA Manual De Usuario

Descargar
Página de 122
20
Po20
up
failed
Global compat check failed 1-10
30
Po30
up
failed
Global compat check failed 1-10
Viewing An Interface-Specific Type-1 Inconsistency
When an interface-specific Type-1 inconsistency occurs, the vPC port on the secondary switch is brought
down while the primary switch vPC ports remain up.The following example shows this type of inconsistency
when there is a switchport mode mismatch.
This example shows how to display the status of the suspended vPC VLAN on the secondary switch:
switch(config-if)#
show vpc brief
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id
: 10
Peer status
: peer adjacency formed ok
vPC keep-alive status
: peer is alive
Configuration consistency status: success
Per-vlan consistency status
: success
Type-2 consistency status
: success
vPC role
: secondary
Number of vPCs configured
: 2
Peer Gateway
: Disabled
Dual-active excluded VLANs
: -
Graceful Consistency Check
: Enabled
vPC Peer-link status
---------------------------------------------------------------------
id
Port
Status Active vlans
--
----
------ --------------------------------------------------
1
Po1
up
1
vPC status
----------------------------------------------------------------------------
id
Port
Status Consistency Reason
Active vlans
------ ----------- ------ ----------- -------------------------- -----------
20
Po20
up
success
success
1
30
Po30
down*
failed
Compatibility check failed -
for port mode
This example shows how to display the inconsistent status ( the VLANs on the primary vPC are not suspended)
on the primary switch:
switch(config-if)#
show vpc brief
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id
: 10
Peer status
: peer adjacency formed ok
vPC keep-alive status
: peer is alive
Configuration consistency status: success
Per-vlan consistency status
: success
Type-2 consistency status
: success
vPC role
: primary
Number of vPCs configured
: 2
Peer Gateway
: Disabled
Dual-active excluded VLANs
: -
Graceful Consistency Check
: Enabled
vPC Peer-link status
---------------------------------------------------------------------
id
Port
Status Active vlans
--
----
------ --------------------------------------------------
1
Po1
up
1
vPC status
   Cisco Nexus 5000 Series NX-OS Interfaces Configuration Guide, Release 5.2(1)N1(1)
98
78-26881-OL  
Configuring Virtual Port Channels
Viewing An Interface-Specific Type-1 Inconsistency