Cisco Systems WSC2960X24PDL Manual De Usuario

Descargar
Página de 112
Purpose
Command or Action
(Optional) Define how often to resend trap messages. The range is 1
to 1000; the default is 30 seconds.
snmp-server trap-timeout seconds
Example:
Switch(config)#
snmp-server trap-timeout
60
Step 9
Returns to privileged EXEC mode.
end
Example:
Switch(config)#
end
Step 10
What to Do Next
The snmp-server host command specifies which hosts receive the notifications. The snmp-server enable
trap 
command globally enables the method for the specified notification (for traps and informs). To enable
a host to receive an inform, you must configure an snmp-server host informs command for the host and
globally enable informs by using the snmp-server enable traps command.
To remove the specified host from receiving traps, use the no snmp-server host host global configuration
command. The no snmp-server host command with no keywords disables traps, but not informs, to the host.
To disable informs, use the no snmp-server host informs global configuration command. To disable a specific
trap type, use the no snmp-server enable traps notification-types global configuration command.
Setting the Agent Contact and Location Information
Beginning in privileged EXEC mode, follow these steps to set the system contact and location of the SNMP
agent so that these descriptions can be accessed through the configuration file.
SUMMARY STEPS
1. configure terminal
2. snmp-server contact text
3. snmp-server location text
4. end
   Catalyst 2960-X Switch Network Management Configuration Guide, Cisco IOS Release 15.0(2)EX
60
OL-29044-01  
Configuring Simple Network Management Protocol
Setting the Agent Contact and Location Information