Cisco Systems VCO/4K Manual De Usuario

Descargar
Página de 18
4-13
Cisco VCO/4K Mechanical Assemblies
78-10334-03
Chapter 4
Storage/Control I/O Module
Removal and Replacement Information
Figure 4-9
Jumper Configuration for DCE/DTE, Serial Ports 1-4
Serial port 4 can be configured to use clock signals by the TRXC4 and RTXC4 signal lines. Jumper JP15
configurations of the clock lines are shown in Figure 4-10. The module is shipped without clock lines
connected.
Figure 4-10 Jumper 15 Configuration of Clock Lines, Serial Port 4
Removal and Replacement Information
Figure 4-11 shows the location of the Storage/Control I/O Module cards in the rear of the VCO system.
The card is located in slots 3 to 4 in nonredundant systems, and in slots 3 to 4 and 5 to 6 in redundant
systems. The label at the base of the card cage identifies where the card(s) is located.
There is a soft start circuit on the card which allows for the Storage/Control I/O Module to be removed
and replaced while the system is running. This should only be done when the system contains redundant
Storage/Control I/O Modules, and when the module to be removed is in standby mode.
1
3
5
7
9
11
13
2
4
6
8
10
12
14
pins
pins
50173
1
3
5
7
9
11
connects TRXC4 to Port 4 Pin 15
connects TRXC4 to Port 4 Pin 17
connects TRXC4 to Port 4 Pin 24
connects RTXC4 to Port 4 Pin 24
connects RTXC4 to Port 4 Pin 17
connects RTXC4 to Port 4 Pin 15
JP15
50174