4-16
Cisco VCO/4K Mechanical Assemblies
78-10334-03
Chapter 4
Storage/Control I/O Module
Troubleshooting
Replacement Procedures
Caution
Follow ESD rules when removing a system component. Use a wrist strap for grounding.
To replace the Storage/Control I/O Module:
Step 1
Place the replacement Storage/Control I/O Module on the antistatic mat or envelope.
Step 2
Verify that the Combined Controller that is to be connected to the Storage/Control I/O Module is not
plugged into the backplane.
Step 3
Verify that all the jumpers on the replacement card correspond with those on the removed
Storage/Control I/O Module.
Verify that the jumper configuration is appropriate for the system configuration.
Refer to the “Serial Ports 1 Through 4 and Jumper Settings” section on page 4-11 for details on jumper
settings for the Storage/Control I/O Module.
Step 4
Grasp the replacement card by the sides of the front panel and align it with the top and bottom card
guides.
Step 5
Push the card inward until it makes contact with the midplane.
Step 6
Firmly push the card toward the midplane. The card fits tightly into the midplane connectors and some
force is required to seat the card back firmly into the midplane connectors.
Step 7
Use a 1/8-inch bladed screwdriver to tighten the mounting screws at the top and bottom of each card into
the tapped holes on the mounting rail.
Step 8
Plug the Combined Controller into the backplane.
Step 9
If installing in a nonredundant system, make sure the system is powered on.
Step 10
If the hard disk drive does not contain the Generic software, install the software. Refer to the system
release notes for instructions on installing the Generic software, backing up and restoring the database,
and licensing.
Troubleshooting
Note
More extensive troubleshooting information is contained in the Cisco VCO/4K
Troubleshooting Guide
.
LEDs Not Illuminated
If either of the LEDs on the Storage/Control I/O Module is not illuminated, corrective action should be
taken. These LEDs are fused powered sources. The fuses are on the Combined Controller and are not
field replaceable. Call Cisco Systems for technical support.