Cisco Systems WSC4500X16SFP Manual De Usuario

Descargar
Página de 680
6-4
Software Configuration Guide—Release 12.2(25)SG
OL-7659-03
Chapter 6      Configuring Supervisor Engine Redundancy Using RPR and SSO
Understanding Supervisor Engine Redundancy
When power is first applied to a switch, the supervisor engine that boots first becomes the active 
supervisor engine and remains active until a switchover occurs.
A switchover will occur when one or more of the following events take place:
The active supervisor engine fails (due to either hardware or software function) or is removed.
A user forces a switchover.
A user reloads the active supervisor engine.
 provides information about chassis and supervisor engine support for redundancy.
RPR Operation
RPR is supported in Release 12.2(12c)EW and later releases. When a redundant supervisor engine runs 
in RPR mode, it starts up in a partially-initialized state and is synchronized with the persistent 
configuration of the active supervisor engine.
Note
Persistent configuration includes the following components: startup-config, boot variables, 
config-register, and VLAN database.
The redundant supervisor engine pauses the startup sequence after basic system initialization, and in the 
event that the active supervisor engine fails, the redundant supervisor engine will become the new active 
supervisor engine.
In a supervisor engine switchover, traffic is disrupted because in the RPR mode all of the physical ports 
restart since there is no state maintained between supervisor engines relating to module types and 
statuses. When the redundant supervisor engine completes its initialization, it will read hardware 
information directly from the module.
SSO Operation
SSO is supported in Release 12.2(20)EWA and later releases. When a redundant supervisor engine runs 
in SSO mode, the redundant supervisor engine starts up in a fully-initialized state and synchronizes with 
the persistent configuration and the running configuration of the active supervisor engine. It 
subsequently maintains the state on the protocols listed below, and all changes in hardware and software 
states for features that support stateful switchover are kept in sync. Consequently, it offers no zero 
interruption to Layer 2 sessions in a redundant supervisor engine configuration.
Table 6-2
Chassis and Supervisor Support
Chassis 
(Product Number)
Supported Supervisor Engines
Catalyst 4507R 
(WS-C4507R)
Supports redundant Supervisor Engine II-Plus (WS-X4013+), 
Supervisor Engine IV (WS-X4515), redundant Supervisor 
Engine V (WS-X4516)
Catalyst 4510R 
(WS-C4510R)
Supports redundant Supervisor Engine V (WS-X4516)