7-5
Software Configuration Guide—Release 12.2(25)SG
OL-7659-03
Chapter 7      Environmental Monitoring and Power Management
Power Management
1400 W DC Service Provider—Uses up to three lines (12.5 A, 15 A, 15 A) of DC input and 
delivers varying amounts of system power ranging from 400 W to 1400 W depending on the 
lines powered. See 
 for more information. (PoE not supported)
4200 W AC—Supports varying amounts of system power and PoE depending on the number of 
inputs powered and input voltage.
Note
All Catalyst 4500 series switch AC-input power supplies require single-phase source AC. The source AC 
can be out of phase between multiple power supplies or multiple AC-power plugs on the same power 
supply because all AC power supply inputs are isolated. Each chassis power supply should have its own 
dedicated branch circuit: 20A for North America and circuits sized to local and national codes for 
International locations.
When you insert power supplies in your switch, use power supplies that are of the same wattage. 
Multi-input power supplies such as 1400 W DC triple-input and 4200 W AC have additional restrictions.   
Read the sections on special considerations for these power supplies. If you mix power supplies, the 
switch will use the one it recognizes first and ignore the other power supply. The power supply status 
displays as err-disable and the summary displays as all zeros (0) for wattage values in the output for the 
show power command.
The following example shows the output for the show power command for mixed power supplies:
Switch# show power
Power                                             Fan     Inline
Supply  Model No          Type       Status       Sensor  Status
------  ----------------  ---------  -----------  ------  ------
PS1     PWR-C45-2800AC    AC 2800W   good         good    good  
PS2     PWR-C45-1000AC    AC 1000W   err-disable  good    n.a.  
*** Power Supplies of different type have been detected***
Power supplies needed by system    :1
Power supplies currently available :1
Power Summary                      Maximum
 (in Watts)              Used     Available
----------------------   ----     ---------
System Power (12V)        328         1360
Inline Power (-50V)         0 
1400
Backplane Power (3.3V) 
10 
40
----------------------   ----
Total Used                338 (not to exceed Total Maximum Available = 750)
Switch#
Power Management Modes
The Catalyst 4500 series switches support two power management modes:
Redundant mode—Redundant mode uses one power supply as a primary power supply and the 
second power supply as a back-up. If the primary power supply fails, the second power supply 
immediately supports the switch without any disruption in the network. Both power supplies must 
be the same wattage. A single power supply must have enough power to support the switch 
configuration.
Combined mode—Combined mode uses the power from all installed power supplies to support the 
switch configuration power requirements. However, combined mode has no power redundancy. If a 
power supply fails, one or more modules might shut down.