Chapter 7      Environmental Monitoring and Power Management
Power Management
The following example shows how to display the current power redundancy mode. The power supplies 
needed by system: 1 indicates that the switch is in redundant mode.
Switch# show power supplies
Power supplies needed by system:1
Switch#
Configuring Combined Mode on a Catalyst 4500 Series Switch
If your switch configuration requires more power than a single power supply can provide, set the power 
management mode to combined mode. Combined mode utilizes the available power for both power 
supplies; however, your switch will have no power redundancy.
To effectively use combined mode, follow these guidelines:
Use power supplies of the same type and wattage (fixed or variable and AC or DC).
If you use power supplies with different types or wattages, the switch will utilize only one of the 
power supplies. 
For variable power supplies, choose a power supply that provides enough power so that the chassis 
and PoE requirements are less than the maximum available power. Variable power supplies 
automatically adjust the power resources at startup to accommodate the chassis and PoE 
requirements.
The 1400 W DC power supply does not support combined mode. If you set the power budget to 2, 
the switch disregards this setting.
If you have the power management mode set to combined mode and only one power supply installed, 
your switch will accept the configuration, but power is available from only one power supply.
When your switch is configured to combined mode, the total available power is not the mathematical 
sum of the individual power supplies. The power supplies have a predetermined current sharing ratio 
(See 
 for more information.)
The maximum available power for chassis and PoE for each power supply are listed in 
To configure combined mode on your Catalyst 4500 series switch, perform this task:
Note
The power redundancy-mode combined command does not work on a Catalyst 4006 switch.
The following example shows how to set the power management mode to combined mode.
Switch (config)# power redundancy-mode combined
Switch (config)# end
Switch#
Command
Purpose
Step 1
Switch#
 
configure terminal
Enters configuration mode.
Step 2
Switch(config)# power redundancy-mode combined
Sets the power management mode to 
combined mode.
Step 3
Switch(config)# end 
Exits configuration mode.
Step 4
Switch#
 
show power supplies
Verifies the power redundancy mode for 
the switch.