Cisco Systems N6KC600164P Manual De Usuario

Descargar
Página de 204
S e n d   d o c u m e n t   c o m m e n t s   t o   n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
6-31
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-18634-01
Chapter 6      Managing the Device Hardware
EPLD Configuration
         25     Apr 28 23:07:28 2008  slot0
Usage for slot:
  642273280 bytes used 
  261824512 bytes free 
  904097792 bytes total
switch# show module
Mod  Ports  Module-Type                      Model              Status
---  -----  -------------------------------- ------------------ ------------
2    32     10 Gbps Ethernet Module          N7K-M132XP-12      ok
5    0      Supervisor module-1X             N7K-SUP1           ha-standby
6    0      Supervisor module-1X             N7K-SUP1           active *
...
switch# attach module 5
...
switch(standby)# dir slot0:
         25     Apr 28 23:07:28 2008  slot0
Usage for slot:
  642273280 bytes used 
  261824512 bytes free 
  904097792 bytes total
Step 4
If there is not at least 120 MB of memory free for the EPLD files, delete some unneeded files, such as 
earlier images, so there is enough free memory.
switch# delete bootflash:n7000-s1-kickstart.4.0.1.bin
switch# attach module 5
switch(standby)#
Step 5
Copy the EPLD image file from the FTP or management server to the bootflash or slot0 memory in the 
active supervisor module. The following example shows how to copy from the FTP server to the 
bootflash memory.
switch# copy ftp://10.1.7.2/n7000-s1-epld.4.0.2.img bootflash:n7000-s1-epld.4.0.2.img
Copy the EPLD image to the standby supervisor.
switch# copy bootflash:n7000-s1-epld.4.0.2.img 
bootflash://sup-standby/n7000-s1-epld.4.0.2.img
You are ready to upgrade the EPLD images (see the 
).
Upgrading EPLD Images
When you start upgrading the EPLD images for a module, the Cisco NX-OS software tries to list the 
current and new versions for each EPLD. If the module is installed and online, the software reports both 
the installed and new versions of each EPLD, and where there is a difference, the software will upgrade 
(or downgrade) to the new version when you confirm that the upgrade should occur. For a module that 
is installed but offline, the software cannot determine the installed versions of its EPLDs so it upgrades 
all of the EPLDs for that module when you confirm the upgrade. For a module that is not installed, the 
software displays an error message and does not upgrade the EPLDs. 
 shows how the software reports the current and new EPLD versions for a module that does 
not need EPLD upgrades. The current and new version numbers for each EPLD are the same.