Cisco Systems N7KF248XT25E Manual De Usuario

Descargar
Página de 204
S e n d   d o c u m e n t   c o m m e n t s   t o   n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
6-14
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-18634-01
Chapter 6      Managing the Device Hardware
Information About Modules
 shows the results for each scenario.
Information About Modules
The following sections explain how you can manage operations for the device modules:
  •
  •
  •
Supervisor Modules
The Cisco Nexus 7010 device has one or two supervisor modules. When it has two supervisors, one 
supervisor is automatically active while the other is in standby mode. If the active supervisor goes down 
or is disconnected for replacement, the standby supervisor automatically becomes active. To understand 
the terms used for the supervisors, see 
.
Supervisor modules are automatically powered up and started with the device. 
Table 6-6
Full Redundancy Mode Scenarios  
Scenario
Power 
Supply 1 
(kW)
Power 
Supply 2 
(kW)
Power 
Supply 3 
(kW)
System 
Usage 
(kW)
Input Source Mode
Power Supply Mode
Result
Available 
Power 
(kW)
Reserve 
Power 
(kW)
Available 
Power 
(kW)
Reserve 
Power 
(kW) 
1
6.0
6.0
8.784
6.0
6.0
6.0
6.0
Available power does not meet 
the device usage requirement.
2
6.0
6.0
3.0
8.784
6.0
9.0
9.0
6.0
Available power for the power 
supply mode is sufficient but 
the available power for the 
input source mode is 
insufficient, so the available 
power does not meet the 
device usage requirement.
3
6.0
6.0
6.0
8.784
9.0
9.0
12.0
6.0
Available power for both 
modes meets the device usage 
requirement, so you can power 
up the entire device. 
Table 6-7
Supervisor Module Terms and Usage in Console Displays 
Module Terms
Fixed or Relative
Usage
module-5 and module-6
Fixed usage
module-5 always refers to the supervisor module in slot 5 and 
module-6 always refers to the supervisor module in slot 6.
sup-1 and sup-2
Fixed usage
sup-1 always refers to the supervisor module in slot 5 and 
 
sub-2 always refers to the supervisor module in slot 6.