Connecting to a Module
Connecting to a Module
At any time, you can connect to any module by using the attach module command. Once you are at the 
module prompt, you can obtain further details about the module by using module-specific commands in 
EXEC mode.
SUMMARY STEPS
1.
attach module number
2.
dir bootflash
DETAILED STEPS
To attach to a module, follow these steps:
You can also use the attach module command to display the standby supervisor module information, 
although you cannot configure the standby supervisor module using this command.
Shutting Down Modules
This section includes the following topics:
  •
  •
Command
Purpose
Step 1
attach module 
slot_number
Example:
switch# attach module 6
switch(standby)# 
Provides direct access to the 
specified module (in this example, 
the standby supervisor module is in 
slot 6). 
Step 2
dir bootflash
Example:
switch# dir bootflash:
   80667580     Feb 21 22:04:59 2008  is855.S7
   22168064     Feb 21 22:04:19 2008  ks855.S7
      16384     Jan 03 19:56:00 2005  lost+found/
Usage for bootflash://sup-local
  234045440 bytes used
 1684602880 bytes free
 1918648320 bytes total
switch# 
Provides the available space 
information for the standby 
supervisor module. 
Note
Use the exit command to 
exit the module-specific 
prompt.
Tip
If you are not accessing the 
switch from a console 
terminal, this step is the 
only way to access the 
standby supervisor module.