7-4
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-18634-01
Chapter 7      Troubleshooting
Troubleshooting the Fabric Modules
The SYSTEM and PWR MGMT LEDs on the supervisor modules indicate that there could be problems 
with the supervisor module or any of the other device modules.
When you start up the device, the supervisor module STATUS and CMP STATUS LEDs are amber while 
the module runs diagnostic tests. When the module passes the diagnostic tests and becomes operational, 
the STATUS and CMP STATUS LEDs become green. For devices that have two supervisor modules, the 
ACTIVE LED is green for the active supervisor module or amber for the standby supervisor module. 
When the SYSTEM and PWR MGMT LEDs are green, the device does not detect any critical system 
problems. Amber, red, or unlit LEDs indicate system problems that you need to resolve, possibly with 
other system modules. 
For a listing of supervisor module LEDs and the conditions that they indicate, see 
To troubleshoot for a hardware problem with the supervisor module, follow these steps until the problem 
is resolved:
Step 1
Check if the STATUS or CMP STATUS LED is amber, red, or unlit on each supervisor module as 
follows:
  •
If either the STATUS or CMP STATUS LED is amber or flashing red, a minor (amber) or critical 
(flashing red) overtemperature condition exists. Contact TAC for assistance (see the 
  •
If the STATUS LED is red, the initialization process detected a parity error condition. Contact TAC 
for assistance (see the 
).
Step 2
If the STATUS and CMP STATUS LEDs are unlit, check the module seating and power connections as 
follows:
a.
Loosen the captive screws on the module so that they are no longer in contact with the chassis.
b.
Unseat the module by pressing the ejector buttons on each end of the module and swinging out each 
ejector lever.
c.
Place one hand on the handle for the module and pull the module part way out of the chassis.
d.
Push the module back into the chassis until it is seated on the midplane.
e.
Rotate both ejector levers until they both touch the front of the module. Make sure that each captive 
screw on the fan tray is aligned with its hole in the chassis.
f.
Securely tighten each captive screw (to 69 N m [8 in-lbs]) to the chassis.
g.
Verify that the Output LED on each power supply is lit. If the Output LED is not lit, troubleshoot 
the power supply unit (see the 
Step 3
If the PCMCIA LED is not lit, the compact flash slot is empty. If you need to load a compact flash card 
in the slot, make sure that the compact flash card is formatted correctly for the slot.
Step 4
Contact TAC for assistance (see the 
).
Troubleshooting the Fabric Modules
The following conditions indicate problems with one or more fabric modules:
  •
The FAB LED on the chassis is amber.
  •
The STATUS LED on the fabric module is red.