Cisco Systems 9124E Manual De Usuario

Descargar
Página de 68
Managing the Switch
30
The gateway address of the first switch should be set to whatever the gateway address is for the 
subnet on which the first switch resides. See 
.
Maintaining the Switch
The Cisco MDS 9124e Switch does not require any regular physical maintenance. However, it is 
critical that environmental conditions, described in ”
” are met to help 
prevent switch failure due to heat stress or improper air flow.
Installing dust covers in empty ports
The dust covers included in the Cisco MDS 9124e Switch shipping carton, (see 
) must be 
inserted in ports where SFPs are not installed. Installing dust covers ensures proper airflow and helps 
reduce dust contamination of the switch.
Replacing an SFP transceiver
In some cases you might need to reinstall an SFP transceiver. To remove an SFP transceiver:
1.
Press and hold the cable release.
2.
Remove the cable from the transceiver.
3.
Pull the bail (wire handle) to release the transceiver.
4.
Grasp the bail, and gently but firmly pull the transceiver out of the port.
5.
Repeat this procedure for the remaining ports as required.
To install a replacement SFP:
1.
Make sure that the bail is in the unlocked position.
2.
Orient the SFP with the appropriate port. See 
.
Table 9
Connecting via a management station
Management 
station
First switch
Second switch
Third switch
Ethernet
192.168.1.09
192.168.1.10
204.1.1.11
204.1.1.12
FCIP
192.168.65.09
192.168.65.10
192.168.65.11
192.168.65.12
Gateway
192.168.1.10
 any, not self
192.168.1.10
192.168.1.10