Power Supply Module Features
Power Supply Module Features
The Cisco ME 3800X and ME 3600X switches support two power supply modules, either AC or DC 
input. You can install two AC or DC input power supply modules, a mix of AC and DC input power 
supply modules, or one power supply and one fan module. The power supply and fan modules are 
hot-swappable.
Caution
Both slots must be occupied either by two power supply modules or a power supply and a fan module. 
Do not run the switch with an empty slot unless you are replacing a faulty power supply or fan module. 
Running the switch with an empty slot triggers an alarm.
Each power supply module contains three fans. The switch can operate safely if one fan fails. A fan 
failure triggers an alarm. When a fan fails, replace the power supply module immediately. 
See
 fo
instructions on installing the AC and DC input power supply and fan module. See 
 for voltage and other specifications.
Power Supply Module LEDs
The power supply module LEDs show the status of the power supply modules. 
 applies to both 
AC and DC input power supply modules.
Figure 1-5
Power Supply Module LEDs
1
Power supply module status LED
2
Power supply input status LED
PSU OK
INPUT
1
2
PSU
207476