46-3
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-21521-01
Chapter 46      Configuring Enhanced Object Tracking
Configuring Enhanced Object Tracking Features
This example configures the tracking of an interface line-protocol state and verifies the configuration:
Switch(config)# track 33 interface gigabitethernet 1/0/1 line-protocol
Switch(config-track)# end
Switch# show track 33
Track 33
  Interface GigabitEthernet1/0/1 line-protocol
  Line protocol is Down (hw down)
    1 change, last change 00:18:28
Configuring a Tracked List
You can configure a tracked list of objects with a Boolean expression, a weight threshold, or a percentage 
threshold. A tracked list contains one or more objects. An object must exist before it can be added to the 
tracked list.
  •
You configure a Boolean expression to specify calculation by using either “AND” or “OR” 
operators. 
  •
When you measure the tracked list state by a weight threshold, you assign a weight number to each 
object in the tracked list. The state of the tracked list is determined by whether or not the threshold 
was met. The state of each object is determined by comparing the total weight of all objects against 
a threshold weight for each object.
  •
When you measure the tracked list by a percentage threshold, you assign a percentage threshold to 
all objects in the tracked list. The state of each object is determined by comparing the assigned 
percentages of each object to the list.
Step 5
track object-number interface 
interface-id 
ip routing
(Optional) Create a tracking list to track the IP routing state of an interface, and 
enter tracking configuration mode. IP-route tracking tracks an IP route in the 
routing table and the ability of an interface to route IP packets.
  •
The object-number identifies the tracked object and can be from 1 to 500.
  •
The interface interface-id is the interface being tracked.
Step 6
delay
 {up seconds [down seconds
| [up secondsdown seconds}
(Optional) Specify a period of time in seconds to delay communicating state 
changes of a tracked object. The range is from 1 to 180 seconds.
Step 7
end
Return to privileged EXEC mode.
Step 8
show track object-number
Verify that the specified objects are being tracked.
Step 9
copy running-config 
startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose