52-4
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-21521-01
Chapter 52      Configuring Online Diagnostics
Running Online Diagnostic Tests
To disable diagnostic testing and return to the default settings, use these commands:
  •
To disable online diagnostic testing, use the no diagnostic monitor switch number test {name | 
test-id
 | test-id-range | all} global configuration command. 
  •
To return to the default health-monitoring interval, use the no diagnostic monitor interval switch 
number
 test {name | test-id | test-id-range | all} global configuration command. 
  •
To configure the switch to not generate a syslog message when the health-monitoring test fails, use 
the no diagnostic monitor syslog global configuration command.
  •
To return to the default failure threshold, use the no diagnostic monitor threshold switch number 
test
 {name | test-id | test-id-range | allfailure count count global configuration command.
Note
The switch number keyword is supported only on Catalyst 3750-X switches.
This example shows how to configure a health-monitoring test:
Switch(config)# diagnostic monitor threshold switch 3 test 1 failure count 50
Switch(config)# diagnostic monitor interval switch 3 test TestPortAsicRingLoopback
Running Online Diagnostic Tests
After you configure online diagnostics, you can manually start diagnostic tests or display the test results. 
You can also see which tests are configured for the switch or switch stack and the diagnostic tests that 
have already run. 
  •
  •
Step 5
diagnostic monitor switch
 number test 
{name | test-id | test-id-range | all}
Enable the specified health-monitoring tests.
The switch number keyword is supported only on Catalyst 3750-X 
switches. The range is from 1 to 9.
When specifying the tests, use one of these parameters:
  •
name
—Name of the test that appears in the show diagnostic content 
command output.
  •
test-id
—ID number of the test that appears in the show diagnostic 
content 
command output.
  •
test-id-range
—ID numbers of the tests that appear in the show 
diagnostic content 
command output.
  •
all
—All of the diagnostic tests.
Step 6
end
Return to privileged EXEC mode.
Step 7
show diagnostic
 {content post | result 
| schedule
 | status | switch
Display the online diagnostic test results and the supported test suites. See 
the 
 for more information.
Step 8
show running-config
Verify your entries.
Step 9
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose