Cisco Systems 3560X Manual De Usuario

Descargar
Página de 1438
 
23-10
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-21521-01
Chapter 23      Configuring Flex Links and the MAC Address-Table Move Update Feature
Configuring Flex Links and MAC Address-Table Move Update
To remove a preemption scheme, use the no switchport backup interface interface-id preemption 
mode
 interface configuration command. To reset the delay time to the default, use the no switchport 
backup interface
 interface-id preemption delay interface configuration command.
This example shows how to configure the preemption mode as forced for a backup interface pair and to 
verify the configuration:
Switch# configure terminal
Switch(conf)# interface gigabitethernet1/0/1
Switch(conf-if)#switchport backup interface gigabitethernet1/0/2 preemption mode forced
Switch(conf-if)#switchport backup interface gigabitethernet1/0/2 preemption delay 50
Switch(conf-if)# end
Switch# show interface switchport backup detail
 
Active Interface Backup Interface State
 
------------------------------------------------------------------------
 
GigabitEthernet1/0/211 GigabitEthernet1/0/2 Active Up/Backup Standby 
Interface Pair : Gi1/0/1, Gi1/0/2
Preemption Mode : forced
Preemption Delay : 50 seconds
Bandwidth : 100000 Kbit (Gi1/0/1), 100000 Kbit (Gi1/0/2)
Mac Address Move Update Vlan : auto
Configuring VLAN Load Balancing on Flex Links
Beginning in privileged EXEC mode, follow these steps to configure VLAN load balancing on Flex 
Links:
To disable the VLAN load balancing feature, use the no switchport backup interface interface-id 
prefer vlan
 vlan-range interface configuration command.
Step 7
show interface
 [interface-id] switchport backup
Verify the configuration.
Step 8
copy running-config startup config
(Optional) Save your entries in the switch startup 
configuration file.
Command
Purpose
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface interface-id
Specify the interface, and enter interface configuration 
mode. The interface can be a physical Layer 2 interface or 
a port channel (logical interface). The port-channel range 
is 1 to 48.
Step 3
switchport backup interface
 interface-id prefer vlan 
vlan-range
Configure a physical Layer 2 interface (or port channel) 
as part of a Flex Links pair with the interface and specify 
the VLANs carried on the interface. The VLAN ID range 
is 1 to 4094.
Step 4
end
 
Return to privileged EXEC mode.
Step 5
show interfaces
 [interface-id] switchport backup
Verify the configuration.
Step 6
copy running-config startup config
(Optional) Save your entries in the switch startup 
configuration file.