Cisco Systems 3560X Manual De Usuario

Descargar
Página de 1438
 
34-12
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-21521-01
Chapter 34      Configuring System Message Logging
Configuring System Message Logging
Beginning in privileged EXEC mode, follow these steps to enable configuration logging:
This example shows how to enable the configuration-change logger and to set the number of entries in 
the log to 500.
Switch(config)# archive 
Switch(config-archive)# log config
Switch(config-archive-log-cfg)# logging enable
Switch(config-archive-log-cfg)# logging size 500
Switch(config-archive-log-cfg)# end
This is an example of output for the configuration log:
Switch# show archive log config all         
 idx   sess           user@line      Logged command
   38    11   unknown user@vty3     |no aaa authorization config-commands 
   39    12   unknown user@vty3     |no aaa authorization network default group radius 
   40    12   unknown user@vty3     |no aaa accounting dot1x default start-stop group 
radius 
   41    13   unknown user@vty3     |no aaa accounting system default 
   42    14           temi@vty4     |interface GigabitEthernet4/0/1 
   43    14           temi@vty4     | switchport mode trunk 
   44    14           temi@vty4     | exit 
   45    16           temi@vty5     |interface GigabitEthernet5/0/1 
   46    16           temi@vty5     | switchport mode trunk 
   47    16           temi@vty5     | exit 
Configuring UNIX Syslog Servers
The next sections describe how to configure the UNIX server syslog daemon and how to define the UNIX 
system logging facility.
Logging Messages to a UNIX Syslog Daemon
Before you can send system log messages to a UNIX syslog server, you must configure the syslog 
daemon on a UNIX server. This procedure is optional. 
Command 
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
archive
Enter archive configuration mode.
Step 3
log config
Enter configuration-change logger configuration mode.
Step 4
logging enable
Enable configuration change logging.
Step 5
logging size entries
(Optional) Configure the number of entries retained in the configuration 
log. The range is from 1 to 1000. The default is 100.
Note
When the configuration log is full, the oldest log entry is removed 
each time a new entry is entered.
Step 6
end
Return to privileged EXEC mode.
Step 7
show archive log config
Verify your entries by viewing the configuration log.