Cisco Systems Cisco ME 3400E Manual De Usuario

Descargar
Página de 100
 
3-17
Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide
OL-16447-01
Chapter 3      Installing and Removing AC- and DC-Power-Supply Modules
Power Supply Settings
Power Supply Settings
  •
Use the no power-supply global configuration command (the default) when installing one 
power-supply module. The switch does not send an alarm when the second power-supply module is 
missing.
  •
Use the power-supply dual global configuration command when installing two power-supply 
modules. When both are operating properly, all applicable LEDs are green, and the switch does not 
send an alarm. If a power-supply module is missing, the switch sends an alarm. An error message 
appears and the appropriate power-supply LED turns red.
  •
Use the power-supply dual dc-feed global configuration command when two DC-input feeds are 
connected to the DC-power source. When both are operating properly, all the applicable LEDs are 
green and the switch does not send an alarm. If only one DC-input feed is connected, and there is at 
least one DC-power-supply module installed, the switch sends an alarm. An error message appears 
and the DC-power-supply LED for the missing DC-input feed turns amber. The LED for the 
connected DC-input feed turns green.
  •
Use the no power-supply dual dc-feed global configuration command when only one DC-input 
feed is connected. The switch does not send an alarm when the second DC-input feed is not 
connected. 
See the switch software configuration guide and switch command reference for more details on these 
settings.