Cisco Systems IE301016S8PC Manual De Usuario
Cisco IE 3010 Switch Getting Started Guide
16
Cisco IE 3010 Switch Getting Started Guide
78-19582-02
Wiring the Power Source
The switches have two power supply slots to support these power supply modules:
•
PWR-RGD-LOW-DC: low-voltage DC (24 to 60 VDC)
•
PWR-RGD-AC-DC: high-voltage AC (100 to 240 VAC) or high-voltage
DC (100 to 250 VDC)
The switch supports these power-supply module combinations:
•
Single low-voltage DC
•
Single high-voltage AC or DC
•
Two high-voltage AC or DC
•
Two low-voltage DC
•
One high-voltage AC or DC and one low-voltage DC
For detailed information on installing the power supply modules and for the
power-supply module specifications, see the hardware installation guide.
power-supply module specifications, see the hardware installation guide.
Grounding the Switch
Follow these steps to connect the switch to a protective ground.
Warning
This equipment must be grounded. Never defeat the ground conductor or
operate the equipment in the absence of a suitably installed ground conductor.
Contact the appropriate electrical inspection authority or an electrician if you
are uncertain that suitable grounding is available. Statement 1024
operate the equipment in the absence of a suitably installed ground conductor.
Contact the appropriate electrical inspection authority or an electrician if you
are uncertain that suitable grounding is available. Statement 1024
Step 1
Use a standard Phillips screwdriver or a ratcheting torque screwdriver with a Phillips head to
remove the ground screw from the cable-side of the switch. You need the screw in Step 4.
remove the ground screw from the cable-side of the switch. You need the screw in Step 4.
Step 2
Strip the 6-gauge ground wire to 0.5 inch
(12.7 mm) ± 0.02 inch (0.5 mm).
(12.7 mm) ± 0.02 inch (0.5 mm).
0.5 inch (12.7 mm)
119516