Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
OL-8787-04
Chapter
Step 4
Push the handles in to fully close.
Hot Swapping the Fan Unit
Step 1
Loosen the captive panel screw.
Step 2
Pull the panel screw down to partially disengage the unit.
Step 3
Slowly pull the unit. The unit will disengage from the connector.
Step 4
Carefully slide the fan out until it is completely removed from its slot.
To install a fan unit:
Step 1
Place the unit into the slot. Slowly slide the fan unit in until it engages into the connector.
Step 2
Using the panel screw, push up to re-engage the unit.
Step 3
Tighten the captive panel screw.
Hot Swapping Power Supplies
The SFS 7012 switch requires a minimum of three power supplies for normal operation. Power supplies
can be hot swapped without powering down the switch. To replace a power supply:
can be hot swapped without powering down the switch. To replace a power supply:
Step 1
Loosen the captive panel screw.
Step 2
Pull the panel screw down to partially disengage the unit.
Step 3
Slowly pull the unit. The unit will disengage from the connector.
Step 4
Carefully slide the power supply out until it is completely removed from its slot.
Step 5
To install a power supply:
Step 6
Place the unit into the slot. Slowly slide the power supply in until it engages into the connector.
Step 7
Using the panel screw, push up to re-engage the unit.
Step 8
Tighten the captive panel screw.