RMON Commands
show rmon alarm
SPS208G/SPS224G4/SPS2024 Command Line Interface Reference Guide
327
25
 
User Guidelines
There are no user guidelines for this command.
Example
The following example displays RMON 1 alarms.
Console# show rmon alarm 1
Alarm 1
-------
Field
Value
OID
1.3.6.1.2.1.2.2.1.10.1
Last Sample Value878128
Interval 30
Sample Typedelta
Startup Alarmrising
Rising Threshold8700000
Falling Threshold78
Rising Event1
Falling Event1
Owner
CLI
Field
Description
Alarm
Alarm index.
OID
Monitored variable OID.
Last Sample Value
The statistic value during the last sampling period. 
For example, if the sample type is delta, this value 
is the difference between the samples at the 
beginning and end of the period. If the sample 
type is absolute, this value is the sampled value at 
the end of the period.
Interval
The interval in seconds over which the data is 
sampled and compared with the rising and falling 
thresholds.