Cisco Systems SFS 7000P Manual De Usuario
3-2
Cisco SFS 7000P InfiniBand Server Switch Hardware Installation Guide, Release 2.5.0
OL-9167-01 Rev. A0
Chapter 3 Installing Field Replaceable Units
Installing a Power Supply or Fan Unit
Failed Power Supplies or Fan Units
The status of power supplies and fan units can be checked using the CLI, the
Chassis Manager, or the Element Manager. The available information includes the
status, the vital product data (VPD), the description of the error or an error code.
Chassis Manager, or the Element Manager. The available information includes the
status, the vital product data (VPD), the description of the error or an error code.
If you suspect that a power supply module has failed, check the LEDs (see the
) and view the status through
the Element Manager.
In most cases, vital information can be retrieved from the console port of
management Ethernet port. See the
management Ethernet port. See the
.
Refer to the Cisco SFS 7000 Series Product Family Chassis Manager User Guide
or Cisco SFS 7000 Series Product Family Element Manager User Guide for more
information.
or Cisco SFS 7000 Series Product Family Element Manager User Guide for more
information.
Installing a Power Supply or Fan Unit
Caution
Never place your hand inside an empty module bay or anywhere inside the
Cisco SFS 7000P switch.
Cisco SFS 7000P switch.
Caution
Unused module bays should always have a Cisco SFS 7000P filler panel over the
bay to ensure proper safety, ventilation, and cooling.
bay to ensure proper safety, ventilation, and cooling.
To insert a power supply or fan unit, follow these steps:
Step 1
Ground yourself appropriately.
Step 2
Remove the filler panel from the power supply bay with a number 1 Phillips
screwdriver, if it is still in place (see
screwdriver, if it is still in place (see