Cisco Catalyst 3850 NetFlow Architecture (Wired and Wireless) 
NetFlow Cisco Catalyst 3850 Overview 
The Cisco Catalyst 3850 supports both ingress and egress FnF on all ports of the switch at line rate. Switch raw 
scalability is up to 24K cached flows, whereas it is 8K for ingress and 16K for egress per UADP ASIC. The Cisco 
Catalyst 3850 supports NetFlow Version 9, with IPv4, IPv6, Layer 2 flows, and sampled NetFlow. TCP flags are 
also exported as part of the flow information. When Cisco Catalyst 3850 switches are stacked together, each 
individual stack member exports its own flows to the collector. The Cisco Catalyst 3850 supports up to 16 flow 
monitors with eight different collectors simultaneously per flow monitor. Microflow policing is supported only for 
wireless clients. 
The FnF feature on the Cisco Catalyst 3850 is enabled on the IP base version and earlier. The Cisco Catalyst 3850 
48-port switch has two UADP ASICs per switch, and the Cisco Catalyst 3850 24-port switch has one UADP ASIC. 
NetFlow Configuration on Cisco Catalyst 3850 Switch 
There are three components of FnF configuration: flow record, flow exporter, and flow monitor. 
Flow Record 
The NetFlow flow record is made up of primary fields and nonprimary fields. Primary fields are the fields from 
packet headers that are used for classifying and characterizing the flow. Additional information can be added to the 
flow record, and this information is contained in nonprimary fields. Match commands as seen in the following are 
used to define primary fields, while collect commands are used to define the nonprimary fields. 
Configuring a Flow Record (Ingress) 
flow record v4 
 match ipv4 tos 
 match ipv4 protocol 
 match ipv4 source address 
 match ipv4 destination address 
 match transport source-port 
 match transport destination-port 
 match interface input 
 collect interface output 
 collect transport tcp flags 
 collect counter bytes long 
 collect counter packets long 
 collect timestamp absolute first 
 collect timestamp absolute last 
 collect counter bytes layer2 long 
Note:    “match interface output” cannot be configured in the ingress flow monitor. In order to get the egress 
interface information, use the “collect interface output” command in an ingress flow record. 
Similarly, “match interface input” is not supported on an egress flow record; use “collect interface input” as shown 