Cisco Systems 200 Manual De Usuario

Descargar
Página de 351
Smartport
Configuring Smartport Using The Web-based Interface
145
Cisco Small Business 200 Series Smart Switch Administration Guide 
10
Workflow4: To rerun a Smartport macro after it has failed, perform the 
following steps:
STEP 1
In the Interface Settings page, select an interface with Smartport type Unknown.
STEP  2
Click Show Diagnostics to see the problem.
STEP  3
Troubleshoot, then correct the problem. Consider the troubleshooting tip below.
STEP  4
Click Edit. A new window appears in which you can click Reset to reset the 
interface.
STEP  5
Return to the main page and reapply the macro using either Reapply (for devices 
that are not switches, routers or APs) or Reapply Smartport Macro (for switches, 
routers or APs) to run the Smartport Macro on the interface.
A second method of resetting single or multiple unknown interfaces is:
STEP 1
In the Interface Settings page, select the Port Type equals to checkbox.
STEP  2
Select 
Unknown
 and click Go.
STEP  3
Click Reset All Unknown Smartports. Then reapply the macro as described above.
TIP
The reason that the macro failed might be a conflict with a configuration on the 
interface made prior to applying the macro (most often encountered with security 
and storm-control settings), a wrong port type, a typo or an incorrect command 
within the user-defined macro, or an invalid parameter setting. Parameters are 
checked for neither type nor boundary prior to the attempt to apply the macro, 
therefore, an incorrect or invalid input to a parameter value will almost assuredly 
cause failure when applying the macro.
Configuring Smartport Using The Web-based Interface
The Smartport feature is configured in the Smartport > Properties, Smartport 
Type Settings and Interface Settings pages. 
For Voice VLAN configuration, se
For LLDP/CDP configuration, see the 
 and 
sections, respectively.