Cisco Systems 11500 Series Manual De Usuario

Descargar
Página de 184
Chapter 2      Cabling and Troubleshooting the CSS
Troubleshooting the CSS Hardware Components
2-38
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-06
Table 2-11
Troubleshooting the CSS 11501
Symptom
Recommended Action
At boot up, the following 
message appears:
CHMGR: Slot 
slot
/
subslot
 
had diagnostic failures - 
NOT STARTING UP
When there is a failure on a CSS 11501 
component, the CSS 11501 attempts the boot 
process three times. If the boot is unsuccessful, 
the CSS generates a log message and saves it in 
the boot.log file. Obtain technical assistance. 
Refer to 
. For information 
on log files, refer to the Cisco Content Services 
Switch Administration Guide
.
During normal CSS operation, 
the following message appears:
Temperature has reached 
x
 
celsius for slot 
number
Check the six fans in the chassis. The 
CSS 11501 is running at a temperature that is 
too high, as indicated by the variable. When a 
fan failure occurs, obtain technical assistance.
You cannot access log or 
archive files on the CSS disk but 
traffic is still passed in and out 
of the CSS.
Replace the disk containing the files. Remove 
the disk and install the replacement in the 
CSS 11501. Refer to the reference sheet that 
comes with the replacement disk. 
After you install the disk in the CSS, you must 
wait 10 seconds before you can reseat or 
remove it.
If the replacement disk does not have the same 
software version that the CSS is running, the 
CSS 11501 will not initialize the disk. You 
must reboot the CSS and configure a primary 
boot record. You can select the CSS software 
currently on the disk or instruct the CSS where 
to locate the CSS software ADI file to install on 
the disk. If you archived an offline version of 
your CSS running-config file, copy it back onto 
the CSS.