Configuration
178  
 AlterPath KVM/net Installation, Administration, and User’s Guide
The following tables describes the parameters that appear on the User 1 and 
User 2 forms.
The following tables describes the parameters that appear on the IP Users 
form.
Table 4-4: User 1 and User 2 forms parameters
Field Name
Definition
Idle Timeout (min)
Sets the maximum time (in minutes) for the session to be idle 
before it is closed. The default value is 3 minutes. The maximum 
value is 60 minutes. A value of 0 disables the idle timeout. 
Screen Saver 
Timeout (min)
Sets the time (in minutes) for the session to be idle before the 
screen saver activates. The default value is 10 minutes. The 
maximum value is 60 minutes. A value of 0 disables the idle 
timeout.
Keyboard Type 
Sets the keyboard type. Choose the type of keyboard connected 
to the User 1 and User 2 ports on the KVM/net. The options from 
the drop-down list are shown in the figure. 
Cycle Time
Change the cycle time (in seconds) within a 3 to 60 seconds 
range. The default is 5 seconds.
Escape Sequences
Redefine the common escape sequence portion of each hot key, 
which allow administrators to perform common actions while 
connected to KVM ports.