Renesas HD74LV1G66A Manual De Usuario

Descargar
Página de 9
HD74LV1G66A 
REJ03D0069-0700  Rev.7.00,  Mar 21, 2008 
 
Page 3 of 8 
Absolute Maximum Ratings 
Item Symbol 
Ratings 
Unit 
Test 
Conditions 
Supply voltage range 
V
CC
 
–0.5 to 7.0 
 
Input voltage range 
*1
 
V
I
 
–0.5 to 7.0 
 
Output voltage range 
*1, 2
 
V
O
 
–0.5 to V
CC
 + 0.5 
Output : H or L 
Input clamp current 
I
IK
 –20 mA 
V
I
 < 0 
Output clamp current 
I
OK
 ±50 mA 
V
O
 < 0 or V
O
 > V
CC
 
Continuous output current 
I
O
 ±25 mA 
V
O
 = 0 to V
CC
 
Continuous current through 
V
CC
 or GND 
I
CC
 or I
GND
 ±50 
mA 
 
Maximum power dissipation 
at Ta = 25°C (in still air) 
*3
 
P
T
 200 mW 
 
Storage temperature 
Tstg 
–65 to 150 
°C 
 
Notes:   
The absolute maximum ratings are values, which must not individually be exceeded, and furthermore no two 
of which may be realized at the same time. 
 
1.  The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are 
observed. 
 
2.  This value is limited to 5.5 V maximum. 
 
3.  The maximum package power dissipation was calculated using a junction temperature of 150°C. 
 
Recommended Operating Conditions 
Item Symbol 
Min 
Max 
Unit 
Conditions 
Supply voltage range 
V
CC
 1.65 
5.5  V 
 
Input voltage range 
V
I
 0 
5.5 V 
 
Input / output voltage range 
V
I/O
 0 
V
CC
 V 
 
0 300 
V
CC
 = 1.65 to 1.95 V 
0 200 
V
CC
 = 2.3 to 2.7 V 
0 100 
V
CC
 = 3.0 to 3.6 V 
Input transition rise or fall rate 
t / 
0 20 
ns / V 
V
CC
 = 4.5 to 5.5 V 
Operating free-air temperature
T
a
 –40 
85  °C 
 
Note:  Unused or floating control inputs must be held high or low.