3 – Managing Fabrics
Zoning a Fabric
3-18
59022-06 A
Q
3.4.2
Using the Zoning Config Dialog
Use the Zoning Config dialog to change the Auto Save and Default Visibility 
configuration parameters. In the faceplate display, open the Zoning menu and 
select Edit Zoning Config to open the Zoning Config dialog shown in 
. After making changes, choose the OK button to put the new values 
into effect.
Figure 3-5.  Zoning Config Dialog
3.4.2.1
FC-SW-2 Auto Save
The FC-SW-2 Auto Save parameter determines whether changes to the active 
zone set that a switch receives from other switches in the fabric will be saved to 
permanent memory on that switch. Changes are saved when an updated zone set 
is activated. Zoning changes are always saved to temporary memory. However, if 
Auto Save is enabled, the switch firmware saves changes to the active zone set in 
both temporary and permanent memory. If Auto Save is disabled, changes to the 
active zone set are stored only in temporary memory which is cleared when the 
switch is reset.
3.4.2.2
Default Visibility
Default visibility determines the level of communication that is permitted among 
ports/devices when there is no active zone set. The default visibility parameter 
can be set differently on each switch. When default visibility is enabled (ALL) on a 
switch, all ports/devices on the switch can communicate with all ports/devices on 
switches that also have default visibility enabled. When Default Visibility is 
disabled (NONE), none of the ports/devices on that switch can communicate with 
any other port/device in the fabric.