Troubleshooting
204515-C
4-5
 
The fiber MDAs use only multimode 62.5/125
µm fiber cable. The Nortel 
Networks 100BASE-FX MDA is not supported on single-mode fiber. SC 
connectors are used on 2-port 100BASE-FX MDAs, and MT-RJ connectors are 
used on 4-port 100BASE-FX MDAs.
Cables for the GBICs vary depending on the specific GBIC type. For details of the 
cable requirements for GBICs, refer to 
.”
Autonegotiation Modes
Port connection problems can occur when a port (or station) is connected to 
another port (or station) that is not operating in a compatible mode (for example, 
connecting a full-duplex port on one station to a half-duplex port on another 
station).
The Passport 8100 modules negotiate port speeds according to the IEEE 802.3u 
autonegotiating standard. The switch adjusts (autonegotiates) its port speed and 
duplex mode to match the best service provided by the connected station, up to 
100 Mb/s in full-duplex mode.
The following autonegotiation problems can occur:
If the connected station uses a form of autonegotiation that is not compatible 
with the IEEE 802.3u autonegotiating standard, the Passport 8100 module 
cannot negotiate a compatible mode for correct operation.
If the autonegotiation feature is not present or is not enabled at the connected 
station, the Passport 8100 module may not be able to determine the correct 
duplex mode.
In both situations, the Passport 8100 module autosenses the speed of the 
connected station and, by default, reverts to half-duplex mode. If the connected 