Chapter 3 Using the console interface 239
Using the Business Policy Switch 2000 Version 1.2
 
 describes the Renumber Stack Units screen options.
Hardware Unit Information screen
The Hardware Unit Information screen (
) lists the switch models, 
including any installed MDA and Cascade modules, that are configured in your 
standalone or stack configuration. In addition, this screen displays the software 
version running on the hardware.
To open the Hardware Unit Information screen:
Choose Display Hardware Units (or press h) from the main menu.
Table 43   
Renumber Stack Units screen options
Option
Description
Current Unit Number
Read-only fields listing the current unit number of each of the configured stack 
units. The entries in this column are displayed in order of their current physical 
cabling with respect to the base unit, and can show nonconsecutive unit numbering 
if one or more units were previously moved or modified. The entries can also 
include unit numbers of units that are no longer participating in the stack (not 
currently active).
MAC Address
Read-only field listing the MAC address of the corresponding unit listed in the 
Current Unit Number field.
New Unit Number
User-settable field showing the current unit number of each unit in the stack. You 
can change any of the fields, as required. You can also delete entries by typing 
zero (0) or using the space bar to clear the field.
Default Value
Current stack order
Range
1 to 8
Renumber units with 
new setting?
Specifies whether to start the renumbering process (default is No). Use the 
spacebar to toggle the selection to Yes.
Renumbering resets the switch with the current configuration values. When you 
select this option, the switch resets, runs a self-test, then displays the Nortel 
Networks logo screen. After you press [Ctrl]-Y at the screen prompt, the console 
screen temporarily displays the (standalone) Business Policy Switch main menu. 
Then, within 20 seconds, the console screen refreshes and displays the main 
menu screen for the stack configuration. The Unit LEDs display the new numbering 
order.
Default Value
No
Range
No, Yes