Chapter 6 Troubleshooting 333
Using the Business Policy Switch 2000 Version 1.2
 
Port connection problems
You can usually trace port connection problems to either a poor cable connection 
or an improper connection of the port cables at either end of the link. To remedy 
these types of problems, make sure that the cable connections are secure and that 
the cables connect to the correct ports at both ends of the link.
Port connection problems are also traceable to the autonegotiation mode or the 
port interface.
Autonegotiation modes
Port connection problems can occur when a port (or station) is connected to 
another port (or station) that is not operating in a compatible mode (for example, 
connecting a full-duplex port on one station to a half-duplex port on another 
station).
The Business Policy Switch negotiates port speeds according to the IEEE 802.3u 
autonegotiating standard. The switch adjusts (autonegotiates) its port speed and 
duplex mode to match the best service provided by the connected station, up to 
100 Mb/s in full-duplex mode as follows:
If the connected station uses a form of autonegotiation that is not compatible 
with the IEEE 802.3u autonegotiating standard, the Business Policy Switch 
cannot negotiate a compatible mode for correct operation.
If the autonegotiation feature is not present or not enabled at the connected 
station, the Business Policy Switch may not be able to determine the correct 
duplex modes.
The Status LED is 
blinking.
A nonfatal error occurred 
during the self-test.
Cycle the power to the switch (disconnect and 
then reconnect the AC power cord).
If the problem persists, contact the Nortel 
Networks Technical Solutions Center.
Table 60   Corrective actions (continued)
Symptom
Probable cause
Corrective action