342 Appendix B Interoperability in a mixed stack configuration
208700-B
 
7
Add the newly configured Business Policy Switch to your existing stack.
Figure 130   Stack Operational Mode screen 
Automatic failover
The automatic failover is a temporary safeguard only. If the stack loses power or is 
reset, the temporary base unit will not power up as the base unit when power is 
restored. For this reason, you should always assign the temporary base unit (assign 
another Business Policy Switch, if available) as the base unit (set the Unit Select 
switch to Base) until the failed unit is repaired or replaced. When a failure of the 
base unit is discovered, the Unit Select switch on the temporary base unit should 
be set to Base.
For detailed information about temporary base units, see Installing the BayStack 
400-ST1 Cascade Module
.
Note: 
If you do not reassign the temporary base unit as the new base 
unit, and the temporary base unit fails, the next unit directly downstream 
from this unit becomes the new temporary base unit. This process can 
continue until there are only two units left in the stack configuration.
                           Stack Operational Mode
                      Current Stack Operation Mode: Pure BPS 2000 Stack
                      Next Stack Operation Mode:    [ Hybrid Stack ]
                      Stack BootP Mac Address Type: [  Stack Mac Address  ]
Use space bar to display choices, press <Return> or <Enter> to select choice.
Press Ctrl-R to return to previous menu.  Press Ctrl-C to return to Main Menu.