Installation 
2.3  Power Supply Wiring and Grounding 
RS2000 series products support dual redundant power supplies – “Power Supply 
1 (PS1)” and “Power Supply 2 (PS2)”. The connections for PS1, PS2 and the fail-
safe relay are located on the terminal block as shown in Figure 14 and Figure 15. 
RSG2200 series products can be equipped with either a Philips Screw Terminal 
Block or a Phoenix Plug Terminal Block. The Philips Screw Terminal Block has 
Philips screws with a compression plate allowing either bare wire connections or 
crimped, terminal lugs. We recommend the use of #6 size ring lugs to ensure 
secure, reliable connections under severe shock or vibration. Both terminal 
blocks have a safety cover which must be removed via two Phillips screws before 
connecting any wires. The safety cover must be re-attached after wiring to 
ensure personnel safety.  Refer to Table 5 below for a description of each 
terminal as well as sections 2.3.1 through 2.3.3 for wiring examples. 
 
Figure 14: RS2000 Series Philips Screw Terminal Block 
 
Figure 15: RS2000 Series Phoenix Plug Terminal Block 
 
Philips Screw Terminal without Cover
Philips Screw Terminal with Cover
Safety Cover
Safety Cover 
Screws
Chassis Ground 
Connection
Surge / Chassis 
Ground Jumper
Terminal
Phoenix Plug Terminal without Cover
Phoenix Plug Terminal with Cover
Safety Cover 
Screws
Safety Cover
Chassis Ground 
Connection
Terminal
Surge / Chassis 
Ground Jumper
19 
RuggedCom
® 
RuggedSwitch
® 
RSG2288 Installation Guide rev103