Technical Specifications 
3 Technical Specifications 
3.1  Power Supply Specifications 
Input Range 
Power Supply Type 
Min 
Max 
Internal 
Fuse 
Rating 
Max. Power 
Consumption
12 – 24 VDC 
10 VDC 
36 VDC 
6.3A(F) 
2
 
48 VDC 
36 VDC 
59 VDC 
3.15A(T)
 2
 
HI (125/250 VDC) 
1
 
HI (110/230 VAC) 
1
 
88 VDC 
85 VAC 
300 VDC 
264 VAC 
2A(T)
 1,2
 
28W 
 
Notes:
  
1.  The “HI” power supply is the same power supply for both AC and DC. 
2.  (F) Denotes fast-acting fuse, (T) denotes time-delay fuse. 
3. Power consumption varies based on configuration. 10/100Base-TX ports 
consume roughly 1W less than fiber optic ports. 
 
3.2  Failsafe Relay Specifications 
Parameter 
Value (Resistive Load) 
Max Switching Voltage 
250VAC, 125VDC 
Rated Switching Current 
2A @ 250VAC 
0.15A @ 125VDC, 2A @ 30VDC 
Max Switching Capacity 
150W, 500VA 
 
3.3  Networking Standards Supported 
Standard 
Description 
IEEE 802.3 
10BaseT 
IEEE 802.3u 
100BaseTX / 100BaseFX 
IEEE 802.3z 
1000BaseSX/LX 
IEEE 802.3ab 
1000BaseTx 
IEEE 802.3x 
Full Duplex Operation, Flow Control 
IEEE 802.1D 
MAC Bridges 
IEEE 802.1Q 
VLAN (Virtual LAN) Tagging 
IEEE 802.1p 
Class of Service 
IEEE 1588 v2 
Precision Time Protocol 
 