3com 5500-SI Manual De Usuario

Descargar
Página de 686
Protection Functions Configuration 187
Configuring BPDU
Protection
Configuration procedure
Configuration example
Enable the BPDU protection function.
<S5500> system-view
System View: return to User View with Ctrl+Z.
[S5500] stp bpdu-protection
As 1000 Mbps ports of an Switch 5500 cannot be shut down, the BPDU protection 
function is not applicable to these ports even you enable the BPDU protection 
function and specify these ports to be MSTP edge ports.
Configuring Root
Protection
Configuration procedure
Configuration example
Enable the root protection function for port Ethernet1/0/1.
Configure in system view.
<S5500> system-view
System View: return to User View with Ctrl+Z.
[S5500] stp interface ethernet1/0/1 root-protection
Configure in Ethernet port view.
<S5500> system-view
System View: return to User View with Ctrl+Z.
[S5500] interface ethernet1/0/1
[S5500-Ethernet1/0/1] stp root-protection
Table 168   Enable the BPDU protection function
Operation
Command
Description
Enter system view
system-view
-
Enable the BPDU protection 
function
stp bpdu-protection
Required
The BPDU protection function is 
disabled by default.
Table 169   Enable the root protection function in system view
Operation
Command
Description
Enter system view
system-view
-
Enable the root protection 
function
stp interface interface-list 
root-protection
Required
The root protection function is 
disabled by default.
Table 170   Enable the root protection function in Ethernet port view
Operation
Command
Description
Enter system view
system-view
-
Enter Ethernet port view
interface interface-type 
interface-number
-
Enable the root protection 
function
stp root-protection
Required
The root protection function is 
disabled by default.