3com 5500-SI Manual De Usuario

Descargar
Página de 686
Logging Function 485
Configuring
Synchronous
Information Output
Function
Synchronous information output function works to prevent users’ input from being 
interrupted by system output. While enabled, this function allows users to view their 
input so far after each system output; thus avoids displaying commands on separate 
lines and increases the system usability.
It is recommended that you disable this function during debugging, as the 
info-center synchronous command can result in displaying of command prompts 
after each piece of debugging information, and therefore increases redundant 
outputs.
Configuration Examples
of Sending Log to Unix
Loghost
Networking Requirement
The networking requirements are as follows:
Sending the log information of the Switch to Unix loghost
The IP address of the loghost is 202.38.1.10
The information with the severity level above informational will be sent to the 
loghost
The output language is English
The modules that allowed to output information are ARP and IP
Networking Diagram
Figure 127   Schematic Diagram of Configuration 
Configuration Procedure
Configuration on the Switch
Enabling info-center
[SW5500]info-center enable
Set the host with the IP address of 202.38.1.10 as the loghost; set the severity 
level threshold value as informational, set the output language to English; set that 
the modules which are allowed to output information are ARP and IP.
[SW5500]info-center loghost 202.38.1.10 facility local4 language 
english
[SW5500]info-center source arp channel loghost log level 
informational
[SW5500]info-center source ip channel loghost log level 
informational
Table 557   Configure the synchronous information output function
Operation
Command
Description
Enter system view
system-view
Configure the synchronous 
information output
info-center synchronous
Optional