Configuration procedure
Configure Switch A.
<S5500 A> system-view
[S5500 A] detect-group 8
[S5500 A-detect-group-8] detect-list 1 ip address 10.1.1.4 nexthop 
192.168.1.2
[S5500 A] ip route-static 10.1.1.4 24 192.168.1.2 detect-group 8
Auto Detect 
Implementation in 
VRRP
You can control the preferences of VRRP backup groups according to auto detect 
results to enable automatic switch between the master and the backup switch as 
follows:
Decrease the preference value of a VRRP backup group when the result of the 
detecting group is unreachable.
Resume the preference of a VRRP backup group when the result of the detecting 
group is reachable.
Configuring the Auto
Detect Function for
VRRP
You need to create a detecting group and perform VRRP-related configurations 
before the following operations.
Configuration Example
Network requirements
Switch B and switch D form VRRP backup group 1, whose virtual IP address is 
192.168.1.10.
Packets sourced from Switch A and destined for Switch C is forwarded by Switch B 
under normal situations.
When the connection between Switch B and Switch C fails, Switch D becomes the 
Master in backup group 1 automatically and the link from Switch D to Switch C, 
the secondary link, is enabled.
Table 593   Configure the auto detect function for VRRP
Operation
Command
Description
Enter system view
system-view
-
Enter VLAN interface 
view
interface vlan-interface vlan_id
-
Enable the auto detect 
function for VRRP
vrrp vrid virtual-router-id track 
detect-group
 group-number [ 
reduced
 value-reduced ]
Required