Password Control Configuration 577
length limitation, the configured minimum password length (if available); the 
enable/disable state of history password recording, the maximum number of history 
password records, the time when the password history was last cleared; the timeout 
time for password authentication; the maximum number of attempts, and the 
processing mode for login attempt failures.
If all the password attempts of a user fail, the system adds the user to the blacklist. 
You can execute the display password-control blacklist command in any view to 
check the names and the IP addresses of such users.
Configuring Password
Aging
To cancel the above configurations, use the corresponding undo commands.
You can configure the password aging time when password aging is not yet enabled, 
but these configured parameters will not take effect.
Table 635   Configure password aging
Operation
Command
Description
Enter system view
system-view
Enable password aging
password-control aging enable Optional
By default, password aging is 
enabled.
Set aging time for super 
passwords
password-control super aging 
aging-time 
Optional
By default, the aging time is 90 
days.
Set aging time for system 
login passwords
password-control aging 
aging-time
Optional
By default, the aging time is 90 
days.
Enable the system to alert 
users to change their 
passwords when their 
passwords will soon expire, 
and specify how many 
days ahead of the 
expiration the system alerts 
the users.
password-control 
alert-before-expire 
alert-time
By default, users are alerted 
seven days ahead of the 
password expiration.
Display the information 
about the global password 
control for all users
display password-control
You can execute the display 
command in any view.
Display the information 
about the password 
control for super 
passwords, including the 
aging time and minimum 
password length.
display password-control super