3com CM 4000 Manual De Usuario

Descargar
Página de 709
Configurator
MPK Devices
5−126
CM 4000 Installation and Operating Manual
CP 3830 DUAL CONFIGURATION
Dedicated Output Panel
Dual CP 3830 panels can be configured so that the second panel is always used for output selection. The output panel’s buttons
will glow amber.
MPK bus
CP 3830
“CP3830IN”
CP 3830
“CP3830OU”
Dedicated
output panel
Figure 5−100.
CM 4000 
“CM1”
CP3830IN
CP−3830
2
00000042
CP3830OU
CP−3830
2
00000043
1
MPK Devices
MPK
Expansion
Pass
Board
CM1
Port
Address
Input Sets
Output Sets
Level Set
Overide Set
Sequence Set
2
CM1
KXYZ−INP
KXYZ−OUT
KXYZ−LEV
Devices
word
In Panel
Out Panel
KXYZ−LEV
KXYZ−OUT
Figure 5−101. Entry for system shown in Figure 5−100.
CP3830IN
Device
Type
CP3830IN
Do the following to connect two CP 3830 panels together with one being an input panel and the other being an output panel:
1.
The Expansion box must be unchecked for both the input and output CP 3830.
2.
The Output Set should be the same for both panels. The compiler requires the LEV SET field to be defined.
The CP 3830 input panel can be independent of the output CP 3830. The output CP 3830 can still change the output
for the input CP 3830 by selecting the new output name and doing a TAKE.
3.
The CP 3830 that is defined as the output panel must have the name of the associated CP 3830 selected in the “In Panel”
field (e.g., CP−3830IN).