3com DUA1750-2BAA01 Manual De Usuario

Descargar
Página de 773
3Com Switch 8800 Configuration Guide 
Chapter 42  HA Configuration
 
42-4 
  Caution: 
When a single Fabric is in position, the load-balance mode is not effective and the 
Fabric changes to the load-single mode automatically. 
 
42.3  Displaying and Debugging HA Configuration 
After the above configuration, execute display command in relevant view to display the 
running of the ACL configuration, and to verify the configuration. Execute debugging 
command in user view to enable HA module debugging function. 
Perform the following configuration in relevant view. 
Table 42-6 Display and debug HA configuration 
Operation 
Command 
Display the status of the Fabric and 
slave board(any view) 
display switchover state [ slot-id ] 
Display the load mode of the Fabric and 
slave board(system view) 
display xbar 
Enable the debugging information 
output of the HA module(user view) 
debugging ha { all | event | message | 
state
 } 
Disable the debugging information 
output of the HA module(user view) 
undo debugging ha  { all  | event  | 
message