3com 3CBLSF26H Manual De Usuario

Descargar
Página de 135
 
4-2 
Configure a new user 
You can use localuser command to configure a new user through the Console Port (see CLI Reference 
Guide)
Forgotten Static IP Address 
If you forget the static IP address that you assigned to the switch, you can use display ip command 
through the Console Port (see CLI Reference Guide). 
Solving LED Issues 
This section lists some issues that are related to the LEDs on the front panel of the switch.  
Gigabit Combo Ports (RJ-45/SFP) 
Link/Activity Status LEDs 
Power LED 
A link is connected, but the Link/Activity LED for the port is off 
There is a problem with this connection. Verify that: 
The switch being connected to is powered on and operating correctly. 
The cable is connected at both ends. 
The cable is not damaged. 
If the connection is to a workstation, that the workstation's network interface is installed and 
configured correctly. 
The correct category of cable is being used for the required link speed. Category 3 cables can be 
used for 10BASE-T operation only. Category 5 cable is required for 100BASE-TX or 1000BASE-T. 
3Com recommends Category 5e or 6 cables for 1000BASE-T operation. 
A fiber cable is connected, but the Module Active LED is off 
Verify that: 
The fiber cable is in good condition. 
The SFP module is correctly inserted. 
A 3Com SFP module is being used. 
The equipment at the far end is installed and correctly configured. 
The Link/Activity LED is on, but network performance is poor 
The switch supports full-duplex auto-negotiation. If the connected device does not support 
auto-negotiation, ensure that it is configured for half-duplex operation only. If the connected device has 
auto-negotiation disabled or overridden, and is configured as full-duplex, the switch will configure the 
link as half-duplex, causing a mismatch that will reduce network performance when data is transmitting 
and receiving simultaneously on the same link. 
Ensure that the connected device has either: 
Auto-negotiation enabled, or 
The ports are configured for half-duplex operation