Panasonic AHR5 Manual De Usuario

Descargar
Página de 3
AHR5
77
NOTES
1. Method of attaching actuating lever
Insert tha lever in the rotating spindle, 
then place the retainer over the spindle to 
lock the lever in place as shown in Fig. 1. 
Be sure that the retainer has snapped 
over the lugs on the rotating spindle, with 
the lugs entering fully into the holes in the 
retainer.
2. Regarding the actuating lever
As an accessory, the standard lever 
(Product No. AHR5801) is available sepa-
rately.
3. Cautions regarding design of actuat-
ing lever
The dimensions of the lever at the mount-
ing section are as shown in Fig. 2. These 
dimensions should be used in the design 
of an alternate actuating lever. The mate-
rial can be stainless steel wire or piano 
wire. The standard lever length is 50 mm 
1.969 inch
. A lever in excess of this length 
would have a weight which could cause 
erroneous operation.
4. Regarding switch mounting
Mount the switch to a smooth surface us-
ing M3 screws. Tighten the screw with 3 to 
5 kg-cm torque. To prevent loosening of 
the mounting screws, it is recommended 
that spring washers be used in combina-
tion with adhesive material for locking the 
screws.
In the mounted condition, the insulating 
distance between each terminal and 
ground should be checked for assurance 
of proper distance.
5. Regarding changes in operating 
characteristics
When selecting the V rotary action switch, 
allow 
±20% to the rated operating and re-
lease forces.
(Example)
OF: 10.2 g-cm max. specification
10.2 
× (100+20%) = 12.24 g-cm
RF: 1.3 g-cm min. specification
1.3 g-cm 
× (100–20%) = 1.04 g-cm
6. Adjustment of the operating object
The positioning of the operating object 
should be such that when direct force is 
not applied to the actuator, the actuator is 
in its free position. The operating object 
should apply force in the operating direc-
tion. The standard value of overtravel to 
be used should be set within the range of 
70% to 100% of the rated O.T. value. Fur-
thermore, if the operating position limit is 
exceeded, the electrical and mechanical 
life of the switch will be shortened.
7. Avoid using V Rotary switches in the 
following conditions:
• Where the ambient temperature ex-
ceeds the range of –25
°C to +65°C 
–13
°F 
to +149
°F
.
• Where the relative humidity exceeds 
85%.
• Where the permissible operating speed 
of 1 to 100
°/sec. is exceed.
• Where the operating speed of 240 cpm. 
is exceeded.
• Where the lever length of 50mm 
1.969inch
 is exceeded.
Rotating spindle
Retainer
Hole (2 places)
Actuating lever
Lug section (2 places)
0.7 DIA. 
.028 DIA.
Stainless steel
52.3
2.059
At time of mounting,
50 mm from center of rotating spindle
Standard lever
AHR5801
d = 0.7
±0.015 DIA.
d = .028
±.001 DIA.
90
°
Less than
0.5R
.020R
1.2
±0.2
.047
±.008
11/2002