3com 5104M-FIB Manual De Usuario

Descargar
Página de 448
SET TRUNK NETWORK_MAP
2-275
SET TRUNK 
NETWORK_MAP
Use the SET TRUNK NETWORK_MAP command to determine if the Network 
Map feature should be extended from one hub to the next hub between Token 
Ring copper trunk ports. This command is valid for ONLine Token Ring modules 
only.
Format
Example
The following command sets the Ring-In port of the Token Ring module in slot 5 
to an internal network map, meaning that this port is connected to another 
trunk port in the same hub:
CB5000>  set trunk 5.1 ring_in network_map internal         
Network map state set to INTERNAL.
Related Commands
SHOW TRUNK
SHOW RING_MAP
slot
Hub slot 1 through 17.
ring_in
Specifies if the port is a Ring-In port.
ring_out
Specifies if the port is a Ring-Out port.
.trunk port
1 or 2 (required only on Model Number 5202M-FR).
setting
External — Ensures a correct port-to-address mapping when you connect 
copper trunk ports on modules in different hubs.
Internal — Ensures a correct port-to-address mapping when you connect 
copper trunk ports on modules in the same hubs.
set trunk
slot
ring_in
setting
ring_out
network_map
.trunk port