3com 5104M-FIB Manual De Usuario

Descargar
Página de 448
SHOW PORT
2-363
Hub Power Budget:
Voltage Type
Voltage Level Watts Capacity Watts Available
Watts Consumed
------------
------------- --------------- --------------- --------------
+5V
 
5.128
367.00
   204.00
163.00
-5V
 
 -5.058
 27.00
  24.75
  2.25
+12V
 
 11.803
 81.50
  42.00
 39.50
-12V
  -11.993
 30.50
  29.50
 
1.00
+2V
 
2.125
 14.30
  10.10
 
4.2
Related Commands
SET POWER
SET POWER MODULE POWER_REQUIREMENTS
Field
Description
Hub Power Modes
Indicates if the hub is set to fault-tolerant or non-fault-tolerant 
mode, if it remains in fault-tolerant status currently (that is, there is 
still enough power to maintain fault tolerance), and if the hub is 
configured to power down when it overheats.
Slot
Slot the row describes.
Class
Power class setting, which determines which modules power down 
if there is a shortage of power in the hub. Lower numbers lose 
power first. ONline™ modules always have highest priority.
Admin Status
Current Admin Status of the slot.
Operating Status
Current Operating Status of the slot.
Voltage Type
Type of voltage being budgeted.
Voltage Level
Actual voltage level of each type.
Watts Capacity
Maximum potential watts produced by the power supplies available 
in the hub.
Watts Available
Number of watts not being used by currently installed modules and 
fans.
Watts Consumed
Number of watts consumed by currently installed modules and 
power supplies.