Panasonic EJ Relays Manual De Usuario

Descargar
Página de 4
EJ (AEJ)
DIMENSIONS 
(Unit: mm 
inch
)
6. Functional shock resistance
Tested sample: AEJ11012, 3 pcs.
Half-wave pulse of sine wave: 11 ms 
Detection time: 10
µs.
Applied direction: 6 directions
Applied cycle: Each of 3 cycles
Y'
Y
X
Z
Z'
X'
X'
Z'
Z
X
Y'
Y
Deenengized condition
Energized condition
1,000m/s
2
1,000m/s
2
1,000m/s
2
1,000m/s
2
1,000m/s
2
1,000m/s
2
External dimensions
<
>
2-M6
300
±20
71.4
58.4
36.0
3.7
3.7
(–)
(+)
52.0
66.0
±0.3
80.0
27.0
70.0
31.5
37.5
15.0
10.0
+1.0
−0.5
34.0
+.039
−.020
1.339
+1.0
−0.5
33.6
+.039
−.020
1.323
2-5.3     dia.
2-.209      dia.
+0.3
−0.1
+.012
−.004
2-M.236
11.811
±.787
2.811
2.299
1.417
.146
.146
2.047
2.598
±.012
3.150
1.063
2.756
1.240
1.476
.591
.394
Notes: 1. Please be warned that contact terminals have polarity. There is no polarity in the coil input line.
2. We will make separate consideration if a coil lead wire connector is desired.
Schematic (Top view)
Mounting hole pattern (Top view)
Tolerance: 
±0.1
 
±.004
Coil terminal
Coil terminal
2 (–)
1 (+)
66.0
2-5.3
2.598
2-.209
Tolerance:
Max. 10mm 
.394inch
:
±0.3
 
±.012
10 to 50mm 
.394 to 1.969inch
:
±0.6
 
±.024
Min. 50mm 
1.969inch
:
±1.0
 
±.039