Optiquest iRIS 320 Manual De Usuario

Descargar
Página de 73
17 
-
 iRIS 220 / iRIS 320, V1.19 User Guide  
 
 
3.4.6 Digital Outputs 
The two digital outputs differ in their electrical configuration, although are identical in their logical operation. 
 
Digital Output 1 is open-drain pull-down and is capable of sinking up to 300mA at 30Vdc.  An integral diode 
provides  transient  protection.    Typically  this  output  could  be  used  to  drive  a  relay  or  lamp  powered  by  an 
auxiliary d.c supply (e.g. 12V).  In this mode, the negative of the load supply must be connected to one of the 
iRIS GND terminals.   
 
WARNING:  Although  it  may  appear  possible  to  directly  control  sensors  by  switching  the  sensor 
negative  supply  lead  using  Output  1,  this  will  introduce  measurement  errors  and  may  possibly 
damage the sensor. Always use Digital Output 2 to power sensors on a timed basis. 
 
Digital Output 2 is a switched 12V output and is capable of sourcing up to 300mA.  Typically this output will 
be used to drive a sensor, relay or lamp powered by the iRIS 12V supply.   
 
WARNING:  Care  should  be  taken  to  avoid  the  load  discharging  the  internal  and/or  external  12V 
battery.    Ensure  adequate  power  supply  charging  capacity  is  available  to  cater  for  the  demands  of 
both the logger and load. 
 
Digital outputs may be programmed to follow the state of the GPRS/CDMA-1X connection so that they will be 
active when a GPRS/CDMA-1X session has been established.  This mode can be used to control power to 
an external data radio when using the iRIS 320 as a radio based gateway.   
 
Alternatively, the outputs can also be programmed to follow a schedule for use in powering loads.  Or they 
can be selected for remote control directly from a HydroTel™ 2000 base station or operate in response to an 
alarm trigger from Sensor #1 for applications such as triggering sediment samplers.  
 
See Section 4.3.12 for details on the digital output modes. 
 
 
 
 
 
 
 
 
 
 
Figure 7 - Digital Output 1 Circuit 
 
 
 
 
 
 
 
 
Figure 8 - Digital Output 2 Circuit 
DOUT2 
DGND 
DOUT1 
+12V 
DGND