Optiquest iRIS 320 Manual De Usuario

Descargar
Página de 73
 iRIS 220 / iRIS 320, V1.19 User Guide - 28 
 
28
 
iQuest (NZ) Ltd  - PO Box 15169, Hamilton, New Zealand  Tel: +64 7 857-0810  Fax: +64 7 857-0811  Email: iquest@iquest.co.nz
 
 
 
Option 5 
When this option is selected you will be prompted to enter an IP address to use for socket B.  Socket B is the 
socket that is used by the iRIS for System DO
  (binary) communication. This is the destination IP address 
used for unsolicited binary calls. 
 
> Skt B IP= 
 
Option 6 
When this option is selected you will be prompted to enter a port number to use for socket B. 
 
> Skt B Port= 
 
Enter  the  remote  port  number  that  you  want  to  have  System  DO
  messages  delivered  to  by  default  (e.g. 
7777).  For the iQuest Data Network use port 7779 or port 7780 unless advised otherwise by iQuest. 
 
Option 7 
Select this option to display the IP Acceptance set-up menu. 
 
Option 8 
Select this option to display the GPRS/CDMA-1X Schedule configuration menu. 
 
Option 9 
Select  this  option  to  display  the  current  network  settings  (GPRS  only)  or  the  wireless  module  identification 
parameters. Example information for both GPRS and CDMA variants is as follows: 
 
GPRS 
IMSI: 530011100721422 
IMEI: 355435000001213 
L/C:  0005,143F 
LOC: 5 
TWR: 18 
ANT: 3 
RSSI: 19,00 
 
IMSI: 
International Mobile Subscriber Information. This is derived from the SIM card 
IMEI: 
International Mobile Equipment Identifier. This is stored in the GPRS module by iQuest during initial 
calibration  and  setup  of  the  iRIS  and  uniquely  identifies  the  hardware  by  manufacturer  and  serial 
number. 
L/C: 
Location/Cell  string.    This is  the  exact cell  identification  string as received  from  the  GPRS module. 
This  is  processed  by  the  iRIS,  which  extracts  and  displays  in  the  information  in  the  next  three 
parameters. The exact nature of these may vary depending on the country and network provider. 
LOC:  The Location ID of the cell that the iRIS is registered with. 
TWR:  The Tower ID of the cell that the iRIS is registered with. 
ANT: 
The Antenna ID of the cell that the iRIS is registered with. 
RSSI:  This displays the Received Signal Strength Indication (RSSI) followed by the Bit Error Rate (BER). 
This is useful for determining the strength and quality of the signal. The possible range of values for 
RSSI is 0-31, with 31 being very strong.  A value of 99 indicates that the RSSI value is not available. 
The iRIS will not attempt to connect to the network if the RSSI is less than six. 
The BER gives an indication of the signal’s quality. Zero is the best (lowest error rate). 
 
CDMA 
ESN:  ABC123 
MDN:  12345678901234 
RSSI: 19
 
 
ESN: 
Electronic Serial Number. This uniquely identifies the wireless module on the network. 
MDN:  Mobile Data Number. The service provider issues this and is the number used to call the module and 
also identify it on incoming or outgoing SMS text messages. 
RSSI:  This  displays  the  Received  Signal  Strength  Indication  (RSSI).  Note,  unlike  the  GPRS  version,  the 
CDMA version does not display a BER (Bit Error Rate) parameter.