3com 5108M-TP Manual De Usuario

Descargar
Página de 66
2 - 12 ONline Ethernet 10BASE-T Module User’s Guide
While there is no fiber in this configuration, the fiber equivalent distance 
can be calculated as follows:
Total link distance: 150 m + 100 m + 100 m + 50 m + 20 m = 420 m
Total equivalent distance of 10BASE-T Modules: 
4 * 420 m + 4 * 165 m = 2340 m 
(signal externally enters four 10BASE-T Modules: 4 * 420 m) 
(signal enters four 10BASE-T Modules from the backplane: 4 * 165 m)
Total equivalent distance: 420 m + 2340 m = 2760 m
Since the total equivalent distance (2760 m) is less than 4200 meters, this is 
a legitimate configuration.
Note that if shielded twisted pair cabling is used, each link in the network 
could run up to 300 meters using Low Squelch (refer to Dip Switch SW3 
(Crossover Mode, Channel Select, Squelch) in Chapter 1 f
or information on 
Squelch levels and the Squelch dip switch setting). Low Squelch is 
acceptable for all shielded twisted pair applications since external noise is 
not a problem.
Redundant Links
You can implement twisted pair link redundancy between ONline System 
Concentrators using Network Management. Figure 2-3 below shows an 
example of a redundant configuration between concentrators using 
10BASE-T Modules.
Figure 2-3.  Redundant Twisted Pair Configuration