3com 2000 TR Manual De Usuario

Descargar
Página de 58
3-4
C
HAPTER
 3: I
NSTALLING
 A
ND
 S
ETTING
 U
P
 T
HE
 M
ODULE
Table 3-1   Front Panel LEDs on the Switch 2000 TR 
The following table describes the LED functions on 
the TR-in-FE Module.
Table 3-2   LEDs on the TR-in-FE Module Panel
Checking the Power Supply
Check the MGMT LED on the Switch. If the MGMT 
LED is not lit, there is a power supply problem. Try the 
following troubleshooting procedures, restarting the 
Switch after each step:
LED Name
Color/State
Indicates
MGMT 
(On the front of 
the Switch)
Green ON
Green fast 
flashing
Green slow 
flashing
Yellow
Yellow flash-
ing
OFF
Switch and TR-in-FE Module are oper-
ating normally.
Software download taking place.
The Switch and TR-in-FE Module are 
initializing (for example, undergoing 
a Power On Self Test).
The Switch failed its Power On Self 
Test (POST).
TR-in-FE Module failed its Power On 
Self Test (POST).
No power to the Switch.
Downlink 
Status
(On front of the 
Switch)
Green ON
Green flash-
ing
Yellow ON
Yellow flash-
ing
OFF
TR-in-FE port enabled and a link is 
present.
Link present but TR-in-FE port dis-
abled.
Switch has not recognized the 
TR-in-FE Module. 
The TR-in-FE Module has failed the 
Power On Self Test (POST).
A link is not present on the TR-in-FE 
port.
LED Name
Color/State
Indicates
Full Duplex
(On TR-in-FE Mod-
ule)
Green ON
Green OFF
Full duplex link is on (port con-
figured for full duplex opera-
tion).
Half duplex link is on.
Port Status
(On TR-in-FE Mod-
ule)
Green ON
Green OFF
A link is present on the Ether-
net port.
The Link is not present on the 
Ethernet Port.
TX
(On TR-in-FE Mod-
ule)
Yellow ON
OFF
The TR-in-FE port is transmit-
ting.
The TR-in-FE port is not trans-
mitting frames.
RX
(On TR-in-FE Mod-
ule)
Yellow ON
OFF
The TR-in-FE port is receiving 
frames.
The TR-in-FE port is not receiv-
ing incoming frames.
MDIX (copper only)
Green ON
RJ-45 configured as a cross-
over.
Green OFF
RJ-45 configured as a static 
connector.