3com 100 TX Manual De Usuario
3-10
C
HAPTER
3: M
AKING
FMS 100-TX H
UB
C
ONNECTIONS
Class II Repeaters
A Class II repeater is a hub with internal delay such that no more than two
hubs can exist between any two DTE devices within a single collision domain
when two maximum-length cable segments are used. The Class II network
topology allows two hubs (or hub stacks) to exist between any two end
stations.
hubs can exist between any two DTE devices within a single collision domain
when two maximum-length cable segments are used. The Class II network
topology allows two hubs (or hub stacks) to exist between any two end
stations.
Figure 3-9 shows a two-repeater collision domain containing two hubs
between two end stations that are located 205 meters apart. This is the total
allowable span for UTP cable.
between two end stations that are located 205 meters apart. This is the total
allowable span for UTP cable.
Figure 3-9 Class II Hubs
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
®
LinkBuilder
REPEATER
1x
1x
1x
1x
1x
1x
1x
100BT
STATUS
1x
1x
1x
1x
1x
1 2 3 4 5 6 7 8 9 10 11 12
13
ACTIVITY
UNIT
LINE
PARTITION
CLS2
3C12345
CLS1
PWR
FAN FAIL
OVERTEMP
COLLISION
Class II configuration
205 meters: maximum UTP distance
5 meters maximum
100 meters maximum
100 meters maximum